Define the night you need to cover
Record the planned hours, starting temperature of the contents, ambient temperature, setpoint and how often the lid opens. Measurements from an already cold fridge can differ from an evening that begins with warm contents. Use the same conditions when comparing models.
| Illustrative reading | Value | What it represents |
|---|---|---|
| Test duration | 9 h | Observed overnight window |
| Meter total | 180 Wh | Energy used |
| Average draw | 20 W | 180 Wh ÷ 9 h |
Read energy at the power source
Use a meter suited to the approved supply and connector. Record total Wh for the whole test, including compressor-off periods. For example, 180 Wh over a nine-hour test is a 20 W average. This is a worked example, independent of any KE model’s stated performance. Keep the meter reading and start/end times with the result.
Compare with the available battery budget
Use the energy actually available at the selected outlet after the reserve and conversion losses. If that budget is 300 Wh, a measured 180 Wh test would leave 120 Wh under those same conditions. Separately verify startup current, voltage range and low-voltage cutoff against the appliance and supply manuals.
What to ask when ordering the fridge
The KE table lists 60 W input and DC 12/24 V. At 60 W continuously for nine hours, a simple upper planning scenario is 540 Wh. Real compressor cycling changes that number. Ask for the exact DC input range, connector, cutoff settings and a consumption test at the intended ambient temperature. If a fleet needs a guaranteed reserve, validate a sample with the actual auxiliary power arrangement.